Review



meh345 15  (World Precision Instruments)


Bioz Verified Symbol World Precision Instruments is a verified supplier
Bioz Manufacturer Symbol World Precision Instruments manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 92

    Structured Review

    World Precision Instruments meh345 15
    Table of Materials
    Meh345 15, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/meh345+15/Microelectrode+Holder+(MEH345)-MEH34515/pmc08011551-237-109-107
    Average 92 stars, based on 1 article reviews
    meh345 15 - by Bioz Stars, 2026-11
    92/100 stars

    Images

    1) Product Images from "Direct-Coupled Electroretinogram (DC-ERG) for Recording the Light-Evoked Electrical Responses of the Mouse Retinal Pigment Epithelium"

    Article Title: Direct-Coupled Electroretinogram (DC-ERG) for Recording the Light-Evoked Electrical Responses of the Mouse Retinal Pigment Epithelium

    Journal: Journal of visualized experiments : JoVE

    doi: 10.3791/61491

    Table of Materials
    Figure Legend Snippet: Table of Materials

    Techniques Used: Convection, Software, Eye Drops

    Related Articles

    Software:

    Article Title: Direct-Coupled Electroretinogram (DC-ERG) for Recording the Light-Evoked Electrical Responses of the Mouse Retinal Pigment Epithelium
    Article Snippet: The user is free to change the light intensity settings at their discretion. table ft1 table-wrap mode="anchored" t5 caption a7 Name of Material/Equipment Company Catalog Number Comments/Description Ag/AgCl (mouth) Electrode WPI Inc EP1 Mouth reference electrode for mouse Ceramic Tile Sutter Instrument CTS Used to cut the glass capillary tube to an appropriate size Cotton Tipped Cleaning Stick Puritan Medical Products 867-WC No Glue To be used as a spacer to improve the fit of the electrode holder assembly Electroretinogram (ERG) System Diagnosys LLC E3 System Visual electrophysiology system to diagnose ophthalmic conditions in vision research and drug trials Bunsen Burner Argos Technologies BW20002460 Or equivlaent to shape glass under flame Glass Capillary Tube (1.5 mm) Sutter Instruments BF150–75 For filling with HBSS and making contact to the cornea Hank’s Buffered Salt Solution (HBSS) Thermo Fisher Scientific Inc 14175–095 Commercially available. .. Maintain at RT In-Line Filter Whatman 6722–5001 To protect vacuum pump from aerosols Low Noise Cable for Microelectrode Holders WPI Inc 5372 Suggested for improving the length and placement of the cables and electrode holder assemblies Magnetic Ball Joint WPI Inc 500871 For magnetically positioning the electrode holder assembly on the stage MatLab Mathworks MatLab: For editing the analysis software MatLab Curvefit Toolbox Mathworks Toolbox for MatLab (only required for editing the analysis software) MatLab Compiler Mathworks Toolbox for MatLab (only required for editing and re-releasing the analysis software) MatLab Runtime version 9.5 Mathworks R2018b (9.5) Required to run the analysis software: https://www.mathworks.com/products/compiler/matlab-runtime.html Microelectrode Holders (45 degrees) WPI Inc MEH345–15 For holding the capillaries Needle (25 ga) Covidien 8881250313 For filling the capillary tubes with HBSS Needle (ground) Electrode Rhythmlink 13mm - one elctrode Subdermal needle electrode (ground) for mouse (13mm long, 0.4mm diameter needle, 1.5m leadwire) Regulator/Power Conditioner Furman P-1800 Or equivalent to remove DC-offset from noise introduced through power line Syringe (12 mL) Monoject 1181200777 For filling the capillary tubes with HBSS T-clip Cole-Parmer 06852–20 For electrode holder assembly Vacuum Desiccator Bel-Art 420120000 Clear polycarbonate bottom & cover Pharmacological treatment Lubricant eye gel Alcon 0078–0429-47 Helps lubricate corneal surface and maintain electrical contact with capillary electrodes Phenylephrine Hydrochloride 2.5% Akorn 17478–201-15 Short acting mydriatic eye drops (for pupil dilation) Proparacaine Hydrochloride 0.5% Akorn 17478–263-12 Local anesthetic for ophthalmic instillation Tropicamide 0.5% Akorn 17478–101-12 Short acting mydriatic eye drops (for pupil dilation) Xylazine AnaSed sc-362949Rx Analgesic and muscle relaxant Zetamine (Ketamine HCl) VetOne 501072 Anesthetic for intramuscular injections Open in a separate window list-behavior=simple prefix-word= mark-type=none max-label-size=4 1.1. ..

    Eye Drops:

    Article Title: Direct-Coupled Electroretinogram (DC-ERG) for Recording the Light-Evoked Electrical Responses of the Mouse Retinal Pigment Epithelium
    Article Snippet: The user is free to change the light intensity settings at their discretion. table ft1 table-wrap mode="anchored" t5 caption a7 Name of Material/Equipment Company Catalog Number Comments/Description Ag/AgCl (mouth) Electrode WPI Inc EP1 Mouth reference electrode for mouse Ceramic Tile Sutter Instrument CTS Used to cut the glass capillary tube to an appropriate size Cotton Tipped Cleaning Stick Puritan Medical Products 867-WC No Glue To be used as a spacer to improve the fit of the electrode holder assembly Electroretinogram (ERG) System Diagnosys LLC E3 System Visual electrophysiology system to diagnose ophthalmic conditions in vision research and drug trials Bunsen Burner Argos Technologies BW20002460 Or equivlaent to shape glass under flame Glass Capillary Tube (1.5 mm) Sutter Instruments BF150–75 For filling with HBSS and making contact to the cornea Hank’s Buffered Salt Solution (HBSS) Thermo Fisher Scientific Inc 14175–095 Commercially available. .. Maintain at RT In-Line Filter Whatman 6722–5001 To protect vacuum pump from aerosols Low Noise Cable for Microelectrode Holders WPI Inc 5372 Suggested for improving the length and placement of the cables and electrode holder assemblies Magnetic Ball Joint WPI Inc 500871 For magnetically positioning the electrode holder assembly on the stage MatLab Mathworks MatLab: For editing the analysis software MatLab Curvefit Toolbox Mathworks Toolbox for MatLab (only required for editing the analysis software) MatLab Compiler Mathworks Toolbox for MatLab (only required for editing and re-releasing the analysis software) MatLab Runtime version 9.5 Mathworks R2018b (9.5) Required to run the analysis software: https://www.mathworks.com/products/compiler/matlab-runtime.html Microelectrode Holders (45 degrees) WPI Inc MEH345–15 For holding the capillaries Needle (25 ga) Covidien 8881250313 For filling the capillary tubes with HBSS Needle (ground) Electrode Rhythmlink 13mm - one elctrode Subdermal needle electrode (ground) for mouse (13mm long, 0.4mm diameter needle, 1.5m leadwire) Regulator/Power Conditioner Furman P-1800 Or equivalent to remove DC-offset from noise introduced through power line Syringe (12 mL) Monoject 1181200777 For filling the capillary tubes with HBSS T-clip Cole-Parmer 06852–20 For electrode holder assembly Vacuum Desiccator Bel-Art 420120000 Clear polycarbonate bottom & cover Pharmacological treatment Lubricant eye gel Alcon 0078–0429-47 Helps lubricate corneal surface and maintain electrical contact with capillary electrodes Phenylephrine Hydrochloride 2.5% Akorn 17478–201-15 Short acting mydriatic eye drops (for pupil dilation) Proparacaine Hydrochloride 0.5% Akorn 17478–263-12 Local anesthetic for ophthalmic instillation Tropicamide 0.5% Akorn 17478–101-12 Short acting mydriatic eye drops (for pupil dilation) Xylazine AnaSed sc-362949Rx Analgesic and muscle relaxant Zetamine (Ketamine HCl) VetOne 501072 Anesthetic for intramuscular injections Open in a separate window list-behavior=simple prefix-word= mark-type=none max-label-size=4 1.1. ..

    other:

    Article Title: Direct-Coupled Electroretinogram (DC-ERG) for Recording the Light-Evoked Electrical Responses of the Mouse Retinal Pigment Epithelium
    Article Snippet: table ft1 table-wrap mode="anchored" t5 caption a7 Name of Material/Equipment Company Catalog Number Comments/Description Ag/AgCl (mouth) Electrode WPI Inc EP1 Mouth reference electrode for mouse Ceramic Tile Sutter Instrument CTS Used to cut the glass capillary tube to an appropriate size Cotton Tipped Cleaning Stick Puritan Medical Products 867-WC No Glue To be used as a spacer to improve the fit of the electrode holder assembly Electroretinogram (ERG) System Diagnosys LLC E3 System Visual electrophysiology system to diagnose ophthalmic conditions in vision research and drug trials Bunsen Burner Argos Technologies BW20002460 Or equivlaent to shape glass under flame Glass Capillary Tube (1.5 mm) Sutter Instruments BF150–75 For filling with HBSS and making contact to the cornea Hank’s Buffered Salt Solution (HBSS) Thermo Fisher Scientific Inc 14175–095 Commercially available.



    Similar Products

    92
    World Precision Instruments meh345 15
    Table of Materials
    Meh345 15, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/meh345+15/Microelectrode+Holder+(MEH345)-MEH34515/pmc08011551-237-109-107
    Average 92 stars, based on 1 article reviews
    meh345 15 - by Bioz Stars, 2026-11
    92/100 stars
      Buy from Supplier

    92
    World Precision Instruments meh34515
    Table of Materials
    Meh34515, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/meh345+15/Microelectrode+Holder+(MEH345)-MEH34515/pmc08011551-14-0-5
    Average 92 stars, based on 1 article reviews
    meh34515 - by Bioz Stars, 2026-11
    92/100 stars
      Buy from Supplier

    Image Search Results


    Table of Materials

    Journal: Journal of visualized experiments : JoVE

    Article Title: Direct-Coupled Electroretinogram (DC-ERG) for Recording the Light-Evoked Electrical Responses of the Mouse Retinal Pigment Epithelium

    doi: 10.3791/61491

    Figure Lengend Snippet: Table of Materials

    Article Snippet: Maintain at RT In-Line Filter Whatman 6722–5001 To protect vacuum pump from aerosols Low Noise Cable for Microelectrode Holders WPI Inc 5372 Suggested for improving the length and placement of the cables and electrode holder assemblies Magnetic Ball Joint WPI Inc 500871 For magnetically positioning the electrode holder assembly on the stage MatLab Mathworks MatLab: For editing the analysis software MatLab Curvefit Toolbox Mathworks Toolbox for MatLab (only required for editing the analysis software) MatLab Compiler Mathworks Toolbox for MatLab (only required for editing and re-releasing the analysis software) MatLab Runtime version 9.5 Mathworks R2018b (9.5) Required to run the analysis software: https://www.mathworks.com/products/compiler/matlab-runtime.html Microelectrode Holders (45 degrees) WPI Inc MEH345–15 For holding the capillaries Needle (25 ga) Covidien 8881250313 For filling the capillary tubes with HBSS Needle (ground) Electrode Rhythmlink 13mm - one elctrode Subdermal needle electrode (ground) for mouse (13mm long, 0.4mm diameter needle, 1.5m leadwire) Regulator/Power Conditioner Furman P-1800 Or equivalent to remove DC-offset from noise introduced through power line Syringe (12 mL) Monoject 1181200777 For filling the capillary tubes with HBSS T-clip Cole-Parmer 06852–20 For electrode holder assembly Vacuum Desiccator Bel-Art 420120000 Clear polycarbonate bottom & cover Pharmacological treatment Lubricant eye gel Alcon 0078–0429-47 Helps lubricate corneal surface and maintain electrical contact with capillary electrodes Phenylephrine Hydrochloride 2.5% Akorn 17478–201-15 Short acting mydriatic eye drops (for pupil dilation) Proparacaine Hydrochloride 0.5% Akorn 17478–263-12 Local anesthetic for ophthalmic instillation Tropicamide 0.5% Akorn 17478–101-12 Short acting mydriatic eye drops (for pupil dilation) Xylazine AnaSed sc-362949Rx Analgesic and muscle relaxant Zetamine (Ketamine HCl) VetOne 501072 Anesthetic for intramuscular injections Open in a separate window list-behavior=simple prefix-word= mark-type=none max-label-size=4 1.1.

    Techniques: Convection, Software, Eye Drops

    Table of Materials

    Journal: Journal of visualized experiments : JoVE

    Article Title: Direct-Coupled Electroretinogram (DC-ERG) for Recording the Light-Evoked Electrical Responses of the Mouse Retinal Pigment Epithelium

    doi: 10.3791/61491

    Figure Lengend Snippet: Table of Materials

    Article Snippet: Microelectrode Holders (45 degrees) , WPI Inc , MEH345–15 , For holding the capillaries.

    Techniques: Convection, Software, Eye Drops